Awọn Atọka Ati Agbara Mita
Iru Apejuwe
Iru | Nkan | Ọna ifihan | Agbara | Titiipa ẹyọkan | Titiipa olubasọrọ ilọpo meji | Fi sii | Ti ara ẹni | Iwọn | Iwọn gige | Olusin | |
ṣayẹwo | olubasọrọ | ṣayẹwo | |||||||||
Iru itumọ ti | GPXN-Q | Bọtini-tẹ | - | 96×48×88 | 91×44 | 3 | |||||
GPXN-T | Bọtini-tẹ | 96×48×55 | 91×44 | 3 | |||||||
Swg. | GPXN1-Q | Imọlẹ | - | - | 96×48×88 | 91×44 | 1 | ||||
GPXN1-T | Imọlẹ | - | 96×48×55 | 91×44 | 1 | ||||||
GPXN4-Q | Bọtini-tẹ | - | - | 144×48×104 | 138×44 | 4 | |||||
GPXN4-T | Bọtini-tẹ | - | 144×48×104 | 138×44 | 4 | ||||||
GPXN5-Q | Bọtini-tẹ | - | - | 96×48×88 | 91×44 | 2 | |||||
GPXN5-T | Bọtini-tẹ | - | 96×48×55 | 91×44 | 2 | ||||||
Insulator kan pẹlu Awọn Atọka 2 | GPXN4-Q/M | Bọtini-tẹ | - | - | 144×48×104 | 138×44 | 4 | ||||
GPXN4-T/M | Bọtini-tẹ | - | 144×48×104 | 138×44 | 4 | ||||||
GPXN4-T/Z | Bọtini-tẹ | 144×48×104 | 138×44 | 4 | |||||||
Pataki Iru | GPXN1-Q/CS | Imọlẹ | - | - | - | 96×48×88 | 91×44 | ||||
GPXNP1-Q/W | Imọlẹ | - | - | - | 96×48×88 | 91×44 | 1 | ||||
GPXN-Q/LCS | Imọlẹ | - | - | 96×48×88 | 91×44 | 3 |
Atọka Foliteji Ti a lo ni Iwọn Akọkọ Unit
Atọka foliteji ni a lo papọ pẹlu insulator lati tọka ipo eletiriki ti Circuit foliteji.
Oluwari foliteji lemọlemọfún GPXN9-C jẹ lilo pẹlu itọka lati tọka ipo itanna.Ijinna iho ti ebute ayẹwo agbara jẹ 14mm tabi 19mm.
Comparator Phase GPXN-C jẹ lilo pẹlu itọka lati tọka ipo eletiriki ti Circuit foliteji giga ati ṣayẹwo lẹsẹsẹ awọn ohun elo itanna.
Ṣiṣayẹwo agbara: fi sii comparator alakoso sinu earthing tabi awọn ebute miiran ti ohun elo foliteji giga.
Ṣiṣayẹwo ipele-ipele: fi sii comparator alakoso sinu ebute iṣayẹwo agbara ipele kanna ti ohun elo giga-voltage meji, ti ina LED ba ni imọlẹ, o fihan pe ipele idanwo ti o ni ipese agbara.
Atọka ipo
Atọka ipo le ṣedasilẹ ipo iṣẹ ati ipo ti ohun elo yi pada bi yipada ati fifọ iyika ninu eto ina.O ti wa ni lilo lọpọlọpọ lori gbogbo iru igbimọ mimic ti yara iṣakoso aringbungbun ati nronu ti ẹrọ iyipada ni ile-iṣẹ agbara, ibudo agbara ati ibudo transformer.Tẹlentẹle ti awọn itọkasi ipo ni igbẹkẹle giga, iwọn jakejado ti foliteji iṣẹ ati igbesi aye gigun.DC ati AC wa fun lilo.
Imọ paramita
Foliteji won won | DC/AC 98V ~ 242V |
Itanle kikankikan | 40 cd/㎡ |
Agbara igbohunsafẹfẹ withstand foliteji | 2kV/1 iseju |
Idaabobo idabobo | ≥100MΩ |
Pipase agbara | ≤1W |
Awọn iwọn otutu ti nṣiṣẹ | -15 ℃ si + 50 ℃ |
Igba aye | 10 ọdun |
Iṣẹ ifihan | Ipo iṣẹ jẹ itọkasi pẹlu pupa/awọ alawọ ewe ati awọn aworan (Gẹgẹbi aṣayan awọn alabara) |
Iwọn ila: | 37.5×37.5×62(mm) |
Iwọn gige: | Φ25(mm) |
Awoṣe | Apejuwe |
GPWZ25-K/2 | Atọka ipo-Circuit-Breaker |
GPWZ25-E/1 | Atọka Ipo-Earthing Yipada |
GPWZ25-B/2 | Atọka-ipo Ikoledanu Mimu |
GPWZ25-B/1 | Atọka-Apapọ ipo |
GPWZ25-K/1 | Atọka ipo-Ipo mẹta Yipada |
Ipo afihan iboju GPAS-72
Awọn GPAS-72 ni tẹlentẹle ipo afihan iboju adopts LED bi awọn ina, pẹlu kekere agbara agbara, ga dede, gun iṣẹ aye, bbl Ati awọn ti o le wa ni loo si gbogbo iru awọn ti switchgears bi ipo afihan iboju pẹlu o yatọ si eto awọn solusan aworan atọka.Pẹlu ọpọlọpọ awọn iṣẹ ti itọkasi alakoso-foliteji, interlock, otutu & iṣakoso ọriniinitutu, itọkasi ipo afọwọṣe, itọkasi ipo fifọ Circuit, itọkasi ipo iyipada ilẹ, itọkasi agbara ti o fipamọ.O jẹ yiyan ti o dara lati rọpo atọka ipo ipo iyipada ẹyọkan ibile.
Imọ paramita
Foliteji won won | AC / DC 110V / 220V |
Igbohunsafẹfẹ agbara withstand | 2kV/min |
Ayika iṣẹ | -25℃ si 55 ℃, ≤90% RH |
Atọka ina luminance | >40cd/m2 |
Igbesi aye iṣẹ | 10 odun |
Ipele Idaabobo | IP42 |
Iwọn | 199x146x63mm |
Iwọn gige | 177x121mm |
Technical ParametersGpj-3100 Series Kukuru Circuit Ati Earth ẹbi Atọka
GPJ-3100 jara ti kukuru kukuru ati itọka ẹbi aiye jẹ apẹrẹ fun idanwo ati afihan Circuit kukuru ati ẹbi aiye ni akoko gidi.O ti lo lati ṣe atẹle circuitry ni RMU, laini ori, laini pinpin okun agbara, oluyipada iru apoti ati awọn aaye miiran ti o jọra.Ni ibamu si ifihan agbara itaniji ti o fihan nipasẹ atọka, awọn oṣiṣẹ le ṣawari ati ge agbegbe aṣiṣe ni iyara nigbati kukuru kukuru tabi aibikita aiye ti o waye ninu ẹrọ iyipo, nitorinaa eto naa le gba agbara ipese fun agbegbe ti kii ṣe ẹbi ni kiakia lati ṣafipamọ akoko ati imudara ṣiṣe.
Imọ Data
1. Kukuru Circuit itaniji lọwọlọwọ: 100A si 1000A akoko idaduro 40ms
2. Earthing itaniji lọwọlọwọ: 20A,30A,40A,50A,60A±10% idaduro akoko 40ms
3. Iwọn otutu: -25 si +70 ℃
4. Ọriniinitutu ibiti: ≦95%
5. Aye asiwaju ipari: 4m
6. Ṣiṣe ipari okun opiti 3.5m
7. Ipese agbara: batiri litiumu 3.6V / 2.45Ah
8. Aago atunto aifọwọyi: 7s, 2hrs, 4hrs, 8hrs
9. Isọjade ti njade: 120 V AC 1A, 30V DC 2A
10.Main oludari iwọn: 95x50x80mm
11.Iwọn iho gige: 91x44 mm
12.Protection kilasi: Main Adarí: IP40, Sensọ: IP65