12/24/40.5kV Earthing Yipada
Standard Ṣiṣẹ Ipò
1. Giga okun ipele ko koja 1000m;
2. Ibaramu afẹfẹ otutu: +45 ℃, -25 ℃;
3. Seismic kikankikan ko koja 8 ìyí;
4. Ọriniinitutu ti o ni ibatan lojoojumọ iye apapọ kii ṣe ju 95%, apapọ oṣooṣu ko ju 90% lọ;
5. Idoti kilasi: II
Ipo pataki: Jọwọ pato nigbati o ba paṣẹ.
12kv Abe ile High Foliteji Ac Earthing Yipada
Main Technical Data
Awọn nkan | Ẹyọ | Data | ||
Foliteji won won | kV | 12 | ||
Ti won won kukuru-akoko duro lọwọlọwọ | kA | 31.5 | ||
Ti won won kukuru-Circuit iye akoko | s | 4 | ||
Ti won won kukuru-Circuit isunmọ lọwọlọwọ | kA | 80 | ||
Ti won won tente oke withstand lọwọlọwọ | kA | 80 | ||
Ti won won idabobo ipele | Ti won won kukuru-akoko agbara | kV | Ipele si aiye / laarin alakoso | 42 |
Imudani ina ti o ni iwọn withstand foliteji | 75 | |||
Darí ìfaradà | Igba | 2000 |
Imọ Specification
GPJN15-12 / 31.5 Earthing yipada ìla ati fifi sori iwọn
GPJN15A-12/31.5 Earthing ipalemo yipada ati fifi sori iwọn
24kv Abe ile High Foliteji AC Earthing Yipada
Main imọ data
Awọn nkan | Ẹyọ | Data | ||
Foliteji won won | kV | 24 | ||
Ti won won kukuru-akoko duro lọwọlọwọ | kA | 31.5 | ||
Ti won won kukuru-Circuit isunmọ lọwọlọwọ | kA | 80 | ||
Ti won won tente oke withstand lọwọlọwọ | kA | 80 | ||
Ti won won kukuru-Circuit iye akoko | s | 4 | ||
Ti won won idabobo ipele | 1min Igbohunsafẹfẹ agbara withstand foliteji | kV | Ipele si aiye / laarin alakoso | 65 |
Imudani itanna withstand foliteji | 125 | |||
Darí ìfaradà | igba | 2000 |
GPJN15-24 / 31.5 Earthing yipada ìla ati fifi sori iwọn
40.5kv Abe ile High Foliteji AC Earthing Yipada
Main imọ data
Awọn nkan | Ẹyọ | Data | ||
Foliteji won won | kV | 36/ 38/40.5 | ||
Ti won won fun igba kukuru duro lọwọlọwọ(4s) | kA | 31.5 | ||
Ti won won kukuru-Circuit isunmọ lọwọlọwọ | kA | 80 | ||
Ti won won tente oke withstand lọwọlọwọ | kA | 80 | ||
Ijinna alakoso | mm | 300, 350, 400 | ||
Ti won won idabobo ipele | (1min) Igbohunsafẹfẹ agbara withstand foliteji | kV | Ipele si aiye / laarin alakoso | 95 |
Imudani itanna withstand foliteji | 185 |
Ila ati fifi sori iwọn
GPJN15-12 (24) (40.5) kV Motorized Earthing Yipada
GPJN15-12(24)/D31.5, GPJN15-12/D40, 50, GPJN15-40.5/D31.5 jara inu ile ga foliteji motorized earthing yipada (kukuru bi: motorized earthing yipada) ti wa ni apẹrẹ fun awọn oye switchgear ibeere ti awọn itanna eto.O jẹ aṣọ fun 3 ~ 40.5KV, 3 alakoso, AC 50 (60) Hz eto agbara ati awọn iru ti ga foliteji switchgears.O jẹ iwulo fun iṣeto iyipada foliteji giga bi aabo ilẹ nigba itọju.
Awọn ọja 'išẹ pade GB1985-2004 High Voltage AC Disconnector ati Earthing Yipada ati awọn ibeere ti bošewa bi daradara bi IEC62271-102: 2002.
Earthing yipada be ni o rọrun ati iwapọ, ina àdánù, rọ isẹ, rorun fifi sori, ìmúdàgba gbona iduroṣinṣin, ati ki o kan gbẹkẹle ina isẹ, pa awọn atilẹba interlocks ni mimu ehoro switchgear pq ibakan, ti a ti orile-ede itọsi.
Awoṣe Awọn ọja Ati Itumọ Rẹ
Awọn paramita ipilẹ
Awọn ọja awoṣe | GPJN15 | ||||
Ti won won foliteji ṣiṣẹ | 12kV | 24kV | 40.5kV | ||
Ti won won fun igba kukuru duro lọwọlọwọ (4S) | 31.5kA | 40kA | 50kA | 31.5kA | |
Ti won won tente oke withstand lọwọlọwọ | 80kA | 100kA | 125kA | 80kA | |
Ti won won kukuru-Circuit isunmọ lọwọlọwọ | 80kA | 100kA | 125kA | 80kA | |
Ipele idabobo: | Ayika akọkọ duro foliteji (iṣẹju 1) | 42kV | 65 kV | 95kV | |
Imudani ina ti o ni iwọn withstand foliteji | 75kV | 125 kV | 185kV | ||
Kọja ijinna lẹhin ṣiṣi ko kere ju | 125mm | 200 mm | 300mm | ||
Iṣakoso foliteji | AC220V | DC220V | DC110V |