ACB Ati MCCB
Lakotan
GPU1/2/3 Series smart air circuit breaker jẹ apẹrẹ awọn ọja ti o dagbasoke nipasẹ wa, foliteji ti AC 50/60Hz, 480V (690V), ti a ṣe iwọn lọwọlọwọ 200A ~ 6300A, lilo ni akọkọ fun pinpin agbara ati awọn iyika aabo fun pinpin agbara Nẹtiwọọki, ṣe idiwọ ipese agbara ati awọn ohun elo itanna bibajẹ lati ẹbi ti apọju apọju, kukuru kukuru, ẹbi aiye, ati bẹbẹ lọ.Breaker tun ni iṣẹ ipinya, o ni ibamu si boṣewa GB 14048.2, IEC 60947-2
Awọn ẹya ara ẹrọ
1. iwapọ be
2. Ko si ijinna flashover Aabo to gaju
3. Agbara giga ti Lori-Pa
4. Smart Iru lori-lọwọlọwọ Idaabobo irin ajo, pẹlu ibaraẹnisọrọ ni wiwo, Le ti wa ni dari nipa kọmputa iṣupọ, mọ awọn iṣẹ latọna jijin.
5. Ifihan iṣẹ ti ammeter, voltmeter
6. Si oke ati isalẹ ti nwọle kii yoo ni ipa lori iṣẹ ṣiṣe ọja
Awoṣe
GPU3 | Afẹfẹ Circuit fifọ gbogbo |
1600 | Shield fireemu lọwọlọwọ |
4 | 3 3-alakoso ko aami 4 4-Ipele |
3M iru smati oludari | Smart adarí Iru 2M: Ifihan tube oni-nọmba, atunṣe bọtini, apakan 3 pẹlu iṣẹ aabo ẹbi aiye Iru 3M: ifihan LCD, atunṣe bọtini, apakan 3 pẹlu iṣẹ aabo ẹbi aiye Iru 3H: ifihan LCD, atunṣe bọtini ati fun ibaraẹnisọrọ, apakan 3 pẹlu earthing ẹbi Idaabobo iṣẹ. |
Igbesoke ọna | Fa-jade iru Iru ti o wa titi |
Ọna asopọ | Petele onirin inaro onirin Awo-ru iwaju onirin |
Aṣayan ẹya ẹrọ | Labẹ-foliteji tripper Interlock mekanical: 2 ṣeto tabi 3 ṣeto fifọ ni inaro lefa interlocked 2 ṣeto fifọ petele tabi inaro interlocked nipasẹ okun irin Ipo titiipa “Ṣi” (titiipa bọtini) Fa-jade 3 ipo yipada Ita asopọ N alakoso transformer |
Ninu=630 | Ti won won lọwọlọwọ(A) |
Akiyesi:
1. Smart oludari ni M iru;Yipada oluranlọwọ: Awọn olubasọrọ ẹgbẹ 4, Ọna asopọ wa ni petele.
2. Smart adarí, shunt Tu ẹrọ, sunmọ itanna, motor drive siseto ati labẹ-foliteji tripper yẹ ki o wa ni pato awọn foliteji iye nigba ti ibere.
Technical Yiyan Table
Iru | Ti won won foliteji ṣiṣẹ Ue(V) | Ti won won idabobo foliteji Ui(V) | Imudani ti o ni idinaduro foliteji Uimp (V) | Shield fireemu Inm lọwọlọwọ (A) | Ti won won lọwọlọwọ Inm (A) | Nọmba alakoso |
GPU1-1250 | AC400 AC690 | AC690, AC1000 | 12000 | 1250 | 200, 400,630, 800,1000, 1250 | 3,4 |
GPU1-2000 | 2000 | 630, 800, 1000, 1250, 1600, 2000 | ||||
GPU1-3200 | 3200 | 2000, 2500, 3600, 4000 | ||||
GPU1-6300 | 6300 | 4000, 5000, 6300 |
Kukuru-Circuit fifọ agbara | Ti won won akoko kukuru withstand lọwọlọwọ Icw (kA)/1s | Išẹ ṣiṣe | |||||
Ti won won max kukuru-yika bibu agbara Icu (kA) | Ti won won ise kukuru-Circuit bibu agbara Ics (kA) | Igbesi aye ẹrọ (awọn akoko) | Igbesi aye itanna (awọn akoko) | ||||
400V | 690V | 400V | 690V | 400V | 690V | ||
50 | 42 | 42 | 15000 | 6000 | |||
80 | 50 | 50 | 40 | 50 | 40 | 15000 | 10000 |
100 | 65 | 80 | 50 | 80 | 50 | 12000 | 8000(5000) |
120 | 75 | 100 | 65 | 100 | 65 | 3000 | 1000 |
GPM11 Mọ Case Circuit fifọ
GPM11Z Smart mọ Case Circuit fifọ
Akopọ ti GPM11/GPM11Z
GPM11 jara in irú Circuit fifọ ni o dara fun AC 50/ 60Hz ti won won foliteji ṣiṣẹ 400V/630V, ti won won lọwọlọwọ soke si 800A ti agbara pinpin nẹtiwọki fun pinpin agbara ati Idaabobo iyika, ipese agbara ati itanna lodi si apọju, labẹ-foliteji ati Awọn eewu kukuru kukuru, o ṣe ilọsiwaju igbẹkẹle ti ipese agbara labẹ awọn ipo lilo deede eyiti kii ṣe ibẹrẹ loorekoore bi iyipada laini laini igbagbogbo ati mọto.Ati pẹlu iṣẹ ipinya bi daradara.O pade pẹlu boṣewa GB/T 14048.2 ati IEC 60947-2.
Awoṣe
GPM11GPM11Z | Ini Case Circuit BreakerSmart Molded Case Circuit fifọ |
100 | Shield fireemu lọwọlọwọ |
H | Agbara fifọ kukuru-kukuru:N: Iru deede S: Standard typeH: Iru fifọ giga |
P | Ọna iṣiṣẹ: Iṣiṣẹ moto: Imudani Protate ṣiṣẹ: Iṣẹ ZDirect (ko si koodu) |
2 | Ẹya Idaabobo Aṣayan: Idaabobo pinpin: Ko si Idaabobo kooduMotor: 2 |
4 | Nọmba alakoso 2: awọn ipele meji 3: awọn ipele mẹta4: awọn ipele mẹrin |
208 | Ọna irin ajo ati koodu awọn ẹya inu inu |
Ninu=100 | Ti won won lọwọlọwọ(A) |
B | 4 Alakoso alakoso N ni awọn oriṣiriṣi 4 ti a samisi bi A, B, C, DA: N alakoso kii yoo fi sori ẹrọ tripper lọwọlọwọ, ati N ti a ti sopọ nigbagbogbo, ko ṣiṣẹ pẹlu awọn ipele 3 miiran.B: N alakoso ko fi sori ẹrọ tripper lọwọlọwọ, ati N alakoso ko ṣiṣẹ pẹlu awọn ipele 3 miiran.C: N alakoso fi sori ẹrọ lọwọlọwọ tripper, ati N alakoso ṣiṣẹ pẹlu miiran 3 awọn ipele.D: N alakoso fi sori ẹrọ lọwọlọwọ tripper, ati N alakoso ti a ti sopọ nigbagbogbo, Ko ṣiṣẹ pẹlu miiran 3 awọn ipele. |
Q | Ona onirin:Iwaju wiwọ awo: QRear ti wiwọ awo: HPlug-ni iru onirin: R |
Akiyesi: 1. Ọna ọna asopọ: ẹhin ti wiwu awo (400, 630's 4P laisi rẹ);plug-in iru onirin (4P laisi rẹ)
2. Awọn ẹya ẹrọ inu ti fi sori ẹrọ ni apa osi ti fifọ.
Technical yiyan tabili fun GPM11Z MCCB
Iru | Ti won won foliteji ṣiṣẹ Ue(V) | Ti won won idabobo foliteji Ui(V) | Ti won won agbara koju foliteji Uimp (V) | Shield fireemu Inm lọwọlọwọ (A) | Ti won won lọwọlọwọ Inm (A) | Nọmba alakoso | Kukuru-Circuit fifọ agbara | Ti won won fun igba kukuru duro duro lọwọlọwọ Icw (kA) 1s | Išẹ ṣiṣe | ||
Ti won won max kukuru-yika bibu agbara Icu (kA) | Ti won won ise kukuru-Circuit bibu agbara Ics (kA) | Igbesi aye ẹrọ (awọn akoko) | Igbesi aye Itanna (awọn akoko) | ||||||||
GPM11Z-100 | AC400 | AC690 | AC8000 | 100 | 32,100 | 3,4 | 65 | 50 | 1 | Ọdun 20000 | 8000 |
GPM11Z-225 | 225 | 225 | 65 | 50 | 2.5 | Ọdun 20000 | 8000 | ||||
GPM11Z-400 | 400 | 400 | 65 | 50 | 5 | 15000 | 7000 | ||||
GPM11Z-630 | 630 | 630 | 65 | 50 | 8 | 10000 | 7000 |
Technical yiyan tabili fun GPM11 MCCB
Iru | Ti won won foliteji ṣiṣẹ Ue | Ti won won insulating foliteji Ui | Imudani ti o ni agbara mu Uimp foliteji | Kilasi fireemu ti wọn ṣe Inm A lọwọlọwọ lọwọlọwọ | Ti won won lọwọlọwọ Ni (A) | Nọmba alakoso | Ti won won max kukuru-Circuit kikan agbara koodu | Ti won won max kukuru -Circuit fifọ agbara | Ti won won ise kukuru-Circuit bibu agbara Ics (kA) | Irin ajo iru ẹrọ | Iṣẹ ṣiṣe (awọn akoko) | |
Gbe | Ko si-Live | |||||||||||
GPM11-63 | 400, 690 | 800,1000 | 8 | 63 | 10, 16, 20, 25, 32, 40, 50, 63 | 3 | N | 10 | 5 | Ooru itanna | 3000 | 7000 |
3,4 | S | 25 | 18 | Ooru itanna | ||||||||
3,4 | H | 50 | 35 | Ooru itanna | ||||||||
GPM11-100 | 100 | 16, 20, 25, 32, 40, 50, 63, 80, 100 | 3 | N | 35 | 25 | Ooru itanna | 3000 | 7000 | |||
3,4 | S | 50 | 35 | Ooru itanna | ||||||||
3,4 | H | 65 | 50 | Ooru itanna | ||||||||
GPM11-160 | 160 | 100, 125, 140, 160 | 3 | N | 35 | 25 | Ooru itanna | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Ooru itanna | ||||||||
3,4 | H | 65 | 50 | Ooru itanna | ||||||||
GPM11-225 | 225 | 100, 125, 140, 160, 180,200, 225 | 3 | N | 35 | 25 | Ooru itanna | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Ooru itanna | ||||||||
3,4 | H | 65 | 50 | Ooru itanna | ||||||||
GPM11-250 | 250 | 100, 125, 140, 160, 180,200, 225,250 | 3 | N | 35 | 25 | Ooru itanna | 1500 | 6500 | |||
3,4 | S | 50 | 35 | Ooru itanna | ||||||||
3,4 | H | 65 | 50 | Ooru itanna | ||||||||
GPM11-400 | 400 | 225, 250, 315, 350, 400 | 3 | N | 35 | 25 | Ooru itanna | 1000 | 4000 | |||
3,4 | S | 50 | 35 | Ooru itanna | ||||||||
3,4 | H | 65 | 50 | Ooru itanna | ||||||||
GPM11-630 | 630 | 400, 500, 630, 630, 700, 800 | 3 | N | 35 | 25 | Ooru itanna | 1000 | 4000 | |||
3,4 | S | 50 | 35 | Ooru itanna | ||||||||
3,4 | H | 65 | 50 | Ooru itanna | ||||||||
GPM11-800 | 800 | 630, 700, 800 | 3,4 | S | 50 | 35 | Ooru itanna | 1000 | 4000 | |||
3,4 | H | 65 | 50 | Ooru itanna |