GPN1-12kV yiyọ AC Irin-agbada paade Switchgear
Ipo ibaramu
Iwọn otutu ibaramu: -25℃~+45℃, aropin ojoojumọ: ≤35℃
Giga: 1000m ( Standard);le to 4500m fun ibere pataki;
Ọriniinitutu ibatan: aropin ojoojumọ ≤95%, aropin oṣooṣu ≤90%;
Iwariri ≤8 iwọn;
Awọn iṣẹlẹ ti o wulo yẹ ki o jẹ ofe kuro ninu inflammables, explosives, corrosives ati gbigbọn nla.
Awoṣe
Awọn ọja ẹya-ara
1) Ọja yii wulo fun GPVN-12kV / 17Kv / 24kV ti a ṣe ti ara wa tabi ti a fi sinu apo idabobo vacuum vacuum tabi ABB's VD4 vacuum circuit breaker.
2) Wa gbóògì iṣeto ni GPVC igbale contactor - fiusi apapo tabi ABB ile VC igbale contactors, eyi ti o le wa ni kq ti FC lupu cubicle, lati pade awọn ina eto ti agbara eweko ati eletan ti miiran ise ati iwakusa katakara.
3) Lilo aluminiomu ti o dara julọ ti alumini-sinkii ti o wa ni irin ti o wa ni erupẹ nipasẹ awọn ohun elo CNC ti o wa ni deede ti a pejọ sinu minisita, ati lilo ilana atunse meji, mu agbara ti minisita pọ si.
4) Enu dada nipasẹ epoxy resini electrostatic powder spray ilana, resistance ti ipata, ifoyina, ikolu ati ki o lagbara adhesion.
5) Awọn minisita ni kikun eto ti paade ti wa ni imuse ni kikun ihamọra, awọn ẹya iṣẹ ti yapa patapata.Nigbati ilẹkun ba ti wa ni pipade, o le ṣaṣeyọri iṣẹ ti ẹrọ fifọ ati iyipada ilẹ.
6) Konge dabaru drive siseto, rii daju awọn trolley pẹlu ti o dara interchangeability.
7) Pipe jc ètò lati pade awọn orisirisi aini ti awọn olumulo, ati ki o kí ė trolley ètò.
8) Yipada ilẹ ti o yara fun ilẹ ati awọn iyika kukuru, ati lati ṣaṣeyọri iṣẹ ina (Motorized).
9) Ọna ti o rọrun ati imunadoko “Aabo marun” ọna titiipa le ṣe idiwọ ilokulo ati rii daju aabo oniṣẹ.
10) Switchgear jẹ ti iru Arc-proof, lori oke ti paati ọkọ akero, Vacuum Circuit breaker kompaktimenti, ati okun ebute oko ti wa ni ipese pẹlu awọn ẹrọ iderun titẹ.
11) Iyẹwu okun ni aaye to pọ, o le ni rọọrun sopọ si ọpọlọpọ awọn kebulu, ati rii daju pe giga fifi sori ẹrọ ti plug okun.
12) Iwọn idaabobo to muna (IP4X), lati ṣe idiwọ ọrọ ajeji ni imunadoko tabi ayabo kokoro.
13) Eto Atẹle aṣayan ti o tẹle atẹle ẹrọ ibojuwo aabo ni iṣẹ iwadii ti ara ẹni ati ibaraẹnisọrọ data, kọnputa ti o ni oye, lati ṣaṣeyọri isakoṣo latọna jijin, telemetry latọna jijin, wiwo latọna jijin, isọdọtun latọna jijin.
14) Pade GB3906, GB / T11022, DL404 ati IEC60298, IEC62271-1 awọn ajohunše, ati nipasẹ kan okeerẹ igbeyewo iru igbeyewo ati Plateau igbeyewo (3000 m).
15) Awọn idanwo ibaramu eletiriki ti o kọja ni yàrá idanwo ohun elo foliteji giga.
A.Technical sipesifikesonu Fun 12Kv switchgear
Nkan | Ẹyọ | Data | |
Foliteji won won | kV | 6-12 | |
Iwọn igbohunsafẹfẹ | Hz | 50/60 | |
Ti won won lọwọlọwọ | A | 630-4000 | |
Ti won won idabobo ipele | 1min agbara igbohunsafẹfẹ (Alakoso si aiye / kọja awọn olubasọrọ ṣiṣi) | kV | 42/48 |
Monomono agbara withstand foliteji (Alakoso si aiye/kọja awọn olubasọrọ ṣiṣi) | kV | 75/85 | |
Busbar akọkọ ti won won lọwọlọwọ | A | 1250,1600,2000,2500,4000 | |
Sub-busbar ti won won lọwọlọwọ | A | 630,1250,1600,2000,2500,3150 | |
Ti won won fun igba kukuru duro lọwọlọwọ(4s) | kA | 16,20,25,31.5,40,50 | |
Ti won won tente oke withstand lọwọlọwọ | kA | 40,50,63,80,100,125 | |
Idaabobo ìyí | Ipilẹ IP4X, IP2X (ilẹkun VCB ṣi silẹ) | ||
Iwọn ila (iwọn/ijinle/giga) | mm | 650(800,1000) /1500(1300,1670,2000) /2300 | |
Iwọn | kg | 500-1200 |
Iyaworan igbekalẹ ti cubicle 630A ~ 1250A
Iyaworan igbekalẹ ti cubicle 1600A ~ 4000A
B.Main imọ sile tabili fun 17.5kV switchgear
Rara. | Oruko | Ẹyọ | Data | |
1 | Foliteji won won | kV | 15/17.5 | |
2 | Ti won won idabobo ipele | Igbohunsafẹfẹ agbara iṣẹju 1 duro foliteji (RMS) | kV | 50 |
Ikanju ina koju foliteji (tente oke) | 95 | |||
3 | Ti won won lọwọlọwọ | A | 630-4000 | |
4 | Ti won won kukuru-Circuit šiši lọwọlọwọ | kA | 50 | |
5 | Igbohunsafẹfẹ agbara | Hz | 50/60 | |
6 | Ti won won kukuru-Circuit ṣiṣe lọwọlọwọ(tente) | kA | 130 | |
7 | Ti won won tente oke withstand lọwọlọwọ | kA | 130 | |
8 | Ti won won kukuru-akoko duro lọwọlọwọ | kA | 50 | |
9 | Itanna aye | igba | 20 | |
10 | Ti won won kukuru-Circuit lọwọlọwọ iye akoko | s | 4 | |
11 | Mechanical aye ti VCB | igba | 10000 | |
12 | Idaabobo ìyí ti cubicle | Ipilẹ IP4X, IP2X (ilẹkun VCB ṣi silẹ) | ||
13 | Iwọn ila (W*D*H) | mm | 800/1000 * 1500/1670 * 2300 | |
14 | Iwọn | kg | 500-1200 |
C.Technical sipesifikesonu fun 24kV switchgear
Nkan | Ẹyọ | Data | |
Foliteji won won | kV | 24 | |
Iwọn igbohunsafẹfẹ | Hz | 50/60 | |
Ti won won lọwọlọwọ | A | 630,1250, 1600, 2500, 3150, 4000 | |
Ti won won idabobo ipele | 1min agbara igbohunsafẹfẹ (alakoso si aiye / kọja awọn olubasọrọ ṣiṣi) | kV |
65 |
Monomono agbara withstand foliteji (alakoso si aiye / kọja awọn olubasọrọ ṣiṣi) | kV |
125 | |
Ti won won fun igba kukuru duro lọwọlọwọ(4s) | kA | 20, 25, 31.5 | |
Ti won won tente oke withstand lọwọlọwọ | kA | 50, 63, 80 | |
Idaabobo ìyí | Ẹka: IP4X, ilẹkun ṣiṣi: IP2X | ||
Iwọn ila (iwọn x ijinle x giga) | mm | 1000(800)x1820(1500)x2430(2300) | |
Iwọn | kg | 1200-1500 |
1. Agbara kukuru kukuru ti CT yẹ ki o ṣe akiyesi lọtọ;
2. Aworan ti ẹhin laini ti njade loke yẹ ki o ni afikun onigun.