Awoṣe
GPVN -12Kv/17.5kV inu ile AC High Foliteji Vacuum Circuit Fifọ
Imọ ni pato
Rara. | Nkan | Ẹyọ | Data | ||||||
1 | Foliteji won won | kV | 7.2 ~ 12 (15/17.5) | ||||||
2 | Iwọn igbohunsafẹfẹ | Hz | 50/60 | ||||||
3 | Ti won won lọwọlọwọ | A | 630.1000.1250 | 1600 | 2000,2500,3150 | 4000 | |||
4 | Ti won won kukuru-Circuit kikan lọwọlọwọ | kA | 20 | 25 | 31.5 | 31.5 | 40 | 40 | 50 |
5 | Ti won won kukuru-Circuit ṣiṣe lọwọlọwọ | kA | 50 | 63 | 80 | 80 | 100 | 100 | 125 |
6 | Ti won won kukuru-akoko duro lọwọlọwọ | kA | 20 | 25 | 31.5 | 31.5 | 40 | 40 | 50 |
7 | Ti won won tente oke withstand lọwọlọwọ | kA | 50 | 63 | 80 | 80 | 100 | 100 | 125 |
8 | Ti won won fa-jade kikan lọwọlọwọ | kA | 12.6 | 12.6 | 16 | 16 | 20 | ||
9 | Ti won won jade-ti-alakoso earthing ẹbi kikan lọwọlọwọ | kA | 17.4 | 21.7 | 27.4 | 27.4 | 34.7 | 34.7 | 43.5 |
10 | Ti won won kukuru-Circuit kikan lọwọlọwọ kikan akoko | Igba | 50 | 30 | 30 | 12 | |||
11 | Ti won won isẹ ọkọọkan | Eyin-0.3s-CO-180-CO | O-180-orundun-CO-180-CO | ||||||
12 | Ti won won kikan lọwọlọwọ ti nikan kapasito bank | A | 630 | ||||||
13 | Ti won won kikan lọwọlọwọ ti pada si pada kapasito bank | A | 400 | ||||||
14 | 1 min.Agbara igbohunsafẹfẹ withstand foliteji | kV | Ipele ipele/si ilẹ: 42, kọja awọn olubasọrọ ṣiṣi:48 | ||||||
15 | Monomono agbara withstand foliteji | kV | Ipele ipele/si ilẹ: 75, kọja awọn olubasọrọ ṣiṣi:85 | ||||||
16 | Igbesi aye ẹrọ | Igba | Ọdun 20000 | ||||||
17 | Akoko ipari | ms | ≤75 | ||||||
18 | Nsii akoko | ms | ≤60 | ||||||
19 | Agbara ipamọ akoko labẹ won won foliteji | s | ≤10 |
Ìla Dimension ti GPVN-12E
GPVN-24
Imọ Specification
Rara. | Nkan | Ẹyọ | Data | |||
1 | Foliteji won won | kV | 24 | |||
2 | Iwọn igbohunsafẹfẹ | Hz | 50/60 | |||
3 | Ti won won lọwọlọwọ | A | 630 1250 1600 2000 2500 3150 4000 | |||
4 | Ti won won kukuru-Circuit kikan lọwọlọwọ | kA | 20 | 25 | 31.5 | 31.5 |
5 | Ti won won kukuru-Circuit ṣiṣe lọwọlọwọ | kA | 50 | 63 | 80 | 80 |
6 | Ti won won-kikuru-yika-kikuru duro lọwọlọwọ(4s) | kA | 20 | 25 | 31.5 | 31.5 |
7 | Ti won won tente oke withstand lọwọlọwọ | kA | 50 | 63 | 80 | 80 |
8 | Ti won won jade-ti-igbese kikan lọwọlọwọ | kA |
|
| 12.6 | 12.6 |
9 | Ti won won kikan lọwọlọwọ ti jade-ti-alakoso aiye ẹbi | kA | 17.4 | 21.7 | 27.4 | 27.4 |
10 | Ti won won bibu igba ti kukuru-Circuit fifọ lọwọlọwọ | Igba | 50 | |||
11 | Ti won won awọn ọna ọna |
| Eyin-0.3s-CO-180-CO | |||
12 | Ti won won kikan lọwọlọwọ ti nikan kapasito bank | A | 630 | |||
13 | Ti won won kikan lọwọlọwọ ti pada-si-pada kapasito bank | A | 400 | |||
14 | 1 min.Agbara igbohunsafẹfẹ withstand foliteji | kV | 50 | |||
15 | Monomono agbara withstand foliteji | kV | 125 | |||
16 | Igbesi aye ẹrọ | Igba | Ọdun 20000 | |||
17 | Akoko ipari | ms | 75 | |||
18 | Nsii akoko | ms | 60 | |||
19 | Akoko ipamọ labẹ iwọn foliteji | s | 10 |